HVAC Humidity

HVAC Humidity

HVAC Humidity / Temperature Transmitters

Indoor Wall

Indoor Wall Humidity Transmitter / Temperature Transmitters Series EE10

Specifications

  • Working range: 0 – 95 %RH
  • Accuracy: ±2 %RH (40 – 60 %RH) and ±3 %RH (10 – 90 %RH)
  • Output: 0-10 Vdc or 4-20 mA (2-wire)
  • Long term stability
  • Optional display
  • Excellent price / performance ratio
  • Humidity / Temperature and Temperature only
  • Temperature output active or passive
  • US-version, will fit electrical outlet box
  • Calibrated against NIST traceable factory standards

Compact

Compact Humidity / Temperature Transmitter Series EE150

Specifications

  • Working range: 10 – 90 %RH
  • Temperature range: -5 – 55 °C (23 – 131 °F)
  • Accuracy: ± 3 %RH (30 – 70 %RH), otherwise ± 5 %RH
  • Analogue Outputs: 0-10 Vdc or 4-20 mA (2-wire)
  • Passive temperature output optional
  • Housing: Polycarbonate, IP65 (NEMA 4) – Duct
  • Stainless steel probe, 6 mm  (1/4″ inch) diameter
  • Long term stability
  • Excellent price / performance ratio
  • Free configuration software
  • Calibrated against NIST traceable factory standards

Economical

Economical Humidity / Temperature Transmitter Series EE160

Specifications

  • Working range: 10 – 95 %RH
  • Temperature range: -40 – 60 °C (-40 – 140 °F)
  • Accuracy: ± 2.5 %RH
  • Analogue Outputs: 0-10 Vdc or 4-20 mA (2-wire)
  • Digital Output: Modbus RTU or BACnet MS/TP (optional)
  • Individual temperature output scaling
  • On-site humidity and temperature adjustment
  • Housing: Polycarbonate, IP65 (NEMA 4) – Wall / Duct
  • Long term stability
  • Excellent price / performance ratio
  • Temperature output active or passive
  • Calibrated against NIST traceable factory standards

High End Humidity

High End Humidity Transmitter / Temperature Transmitter Series EE210

Specifications

  • Working range 0 – 100 %RH
  • Temperature range: -40 – 60 °C (-40 – 140 °F)
  • Accuracy: see data sheet
  • Output: 0-5 / 0-10 Vdc or 4-20 mA (2-wire)
  • Calculated output values, like dewpoint, mixing ratio, partial pressure, etc.
  • Housing: Polycarbonate, IP65 (NEMA 4) – wall, duct and remote probe
  • Scalable temperature output
  • Radiation shield HA010501 for EE210-Outdoor version
  • Display in cover optional
  • Excellent long term stability
  • Calibrated against NIST traceable factory standards

Condensation Monitor

Condensation Monitor Series EE46

Specifications

  • Working range: 10 – 100 %RH
  • Switching point at 20 °C: 90 ± 3 % RH
  • Output: potential free relay SPDT
  • Pipe, duct and wall mounting
  • Excellent price / performance ratio
  • Calibrated against NIST traceable factory standards

  Data Sheet Accessories & Filter Caps
Manual Radiationshield
 IP / NEMA – a comparison
Measuring Humidity – Basic
Humidity Calibration – Basic
Humidity Sensor Elements

Please note: Manual data files can be quite large, please be patient while downloading.
The manuals are for information purposes only and shouldn’t be used for operating the instrument