Ultrasonic Inline Flow Meter

 

Technical Inquiries

support-form3

JLC International distributes many different kinds of ultrasonic inline liquid flow meters for multiple types of industries and uses. Of which we are able to provide three different inline small bore ultrasonic flow meters:

  • Light-Duty Ultrasonic Flowmeter Atrato Series 700
  • Industrial Ultrasonic Flowmeter Atrato Series 70P
  • Chemical Inert Ultrasonic Flowmeter MetraFlow Series 240

This technology allows for an astonishing accuracy over very wide flow ranges across the whole span. With a rugged, clean bore construction, the ultrasonic inline flow meters are perfect for a wide-range of low flow applications. Furthermore, the USB connection of the Atrato flow meter series 700 and 240 allows monitoring the rate and total directly on a laptop for convenience and ease of use. One can alter the operating parameters for pulse resolution and units. This can make utilization of this flow meter a much easier task.

The MetraFlow stands out, the reason for its own label, because the flow tube is entirely made of Perfluoroalkoxy, better known as PFA, which makes the unit basically chemically inert.

Time of Flight Measuring System

The measurement of the low flow rates of liquids in small tubes is very hard with conventional transit time ultrasonic techniques for multiple reasons. If a diametrical beam is used, the defining equation for the transit time difference between the upstream/downstream directions has a constant proportionality, which includes the diameter of the tube. Therefore, as the tube diameter becomes smaller, the transit time difference for the given velocity becomes proportionally smaller.

The Atrato ultrasonic inline liquid flow meters use a time of flight measuring system that measures the upstream and the downstream flight times. Half the difference is the velocity of the fluid. This patented system is capable of measuring these time differences with an accuracy that is better than 250 picoseconds. Since the pipe geometry is known, the pulse output will be accurate for the volume passed. It is enhanced even further by the primary signal to noise ratio, typically at 2000:1, but ranging higher to 3000:1.

Read More

Benefits

  • High reliability
  • No moving parts
  • Fast response
  • Through bore design
  • OEM versions
  • Better long-term results
  • Cost-effective and highly accurate
  • Simple design
  • Easy to use and install

Features

  • ±1.0% of reading
  • ±0.1% repeatability
  • Several flow ranges, down to 2 ml/min (0.032 gph)
  • Analogue and Pulse outputs
  • USB interface on Series 700 and 240
  • Choice of seals
  • One piece of PFA flow tube on MetraFlow
  • Choice of end fittings
  • 10-24 Vdc
  • 60°C or 110°C Max
  • Flow switch
  • Rate and total option
  • 200:1 turndown

Having over 40 years of experience in flow meter innovation, their manufacturer, Titan Enterprises, supplies flow measurement solutions to many different industries, such as medical, industrial, pharmaceutical, food and drink, laboratory and much more. Their top-of-the-line flow meters can handle low flows from laminar to turbulent over a range of 200:1. Being largely immune from viscosity, the accuracy is better than ±1.0%.

The Atrato is a breakthrough in flow meter technology and is ideal for many different purposes:

  • Fuel Cells
  • Chemical and Petrochemical
  • Pilot plant
  • Semiconductor plant
  • OEM applications
  • Drink dispensing
  • Laboratory tests
  • Cooling equipment
  • Active flow alarms

At JLC International, we are proud to distribute Titan’s Atrato inline small bore ultrasonic flow meters to serve any and all of your purposes. If you are interested or want to learn more about what we are able to provide, please contact us today by calling: 1-888-358-2518.


Chemical Inert Low Flow Ultrasonic Inline Liquid Flowmeter
Atrato MetraFlow Series 240

Specifications

  • Two flow ranges:
    • 0.02 – 1.00 l/min (0.32 – 15.85 gph)
    • 0.10 – 5.00 l/min (1.585 – 79.25 gph)
  • Accuracy:
    • ± 1.0% of reading at calibration temperature; standard at 20 °C (68 °F)
    • ± 0.5% FSD for all other
  • Repeatability: ± 0.1% + 0.02% FSD
  • Flow tube: one piece chemical inert Perfluoroalkoxy (PFA); ID 1/8″ and 1/4″
  • Supply voltage: 12 – 24 Vdc or USB 5 Vdc with limited capability
  • Turn-down minimal 50 : 1
  • Temperature rating: -10 – +60 °C (14 – 140 °F)
  • K-factor adjustable; max. considering flow and frequency
  • Pressure rating: depends on tube size and temperature max. 2770 kPa (400 psi)
  • Outputs:
    • NPN (nFET) and PNP (pFET)
    • 0 – 5 / 10 V or 4 – 20 mA – scalable
    • USB interface for configuration and monitoring
  • Liquid crystal display
  • Process connections, 150 mm tube tails
  • Electrical Connections: 8 conductor 1 meter (3 ft) cable, flying leads
  • Immune for changes of fluid velocity profile and Reynolds number
  • No moving parts or obstructions
  • Configuration and monitoring software included

*) provisional text per 06/19/18, small details may still change


Ultra Low and Low Flow Ultrasonic Inline Liquid Flow meter
Industrial Atrato Series 70P

Atrato-70p_small

Specifications

  • Four flow ranges:
    • 0.002 – 0.500 l/min (0.0005 – 0.132 gpm)
    • 0.01 – 1.50 l/min (0.0026 – 0.396 gpm)
    • 0.03 – 5.00 l/min (0.008 – 1.32 gpm)
    • 0.1 – 15.0 l/min (0.0264 – 3.96 gpm)
  • Accuracy: ± 1.0% of reading over 2 – 100% of the flow range
    ± 2.0% of reading over 0 – 2% of the flow range
  • Repeatability: ± 0.1% + 0.005% of FSD
  • Supply voltage: 8 – 24 Vdc
  • Temperature rating: -10 – +65 °C (14 – 149 °F)
  • Pressure rating: 20 bar (290 psi); optional 60 bar (870 psi)
  • Pulse output: NPN and PNP
  • Flow tube materials; PEEK® and 316L Stainless Steel
  • O-ring Viton or Nitrile, EPDM, Silicone
  • Process connections: 1/4″ NPT or BSP female, stainless steel
  • Electrical connections: 4-pin plug, M12 thread
  • Enclosure: 316 Stainless Steel and ABS cover; protection class IP65 / NEMA 4X
  • No moving parts


Ultra Low and Low Flow Ultrasonic Inline Liquid Flowmeter
Light-Duty Atrato Series 700

inline flow meter

Specifications

  • Four flow ranges:
    • 0.002 – 0.500 l/min (0.0005 – 0.132 gpm)
    • 0.007 – 1.70 l/min (0.0018 – 0.450 gpm)
    • 0.02 – 5.00 l/min (0.0053 – 1.32 gpm)
    • 0.1 – 20.0 l/min (0.0264 – 5.28 gpm)
  • Accuracy: ± 1.0% of reading
  • Repeatability: ± 0.1% over 25 – 100% of the range
    ± 0.5% over 0 – 25% of the range
  • Supply voltage: 10 – 24 Vdc
  • Turn-down minimal 200 : 1
  • Temperature rating: -10 – +60 °C (14 – 140 °F)
    -10 – +110 °C (14 – 230 °F) optional
  • K-factor adjustable; max. considering flow and frequency
  • Pressure rating: 10 bar (145 psi) / 30 bar (435 psi)
  • Outputs: Pulse NPN or PNP – to replace pulwse flowmeters – max. 400 Hz
    Programmable hardwired relay
    Analogue 0 – 5 / 10 V or 4 – 20 mA – scalable
  • USB interface for configuration and monitoring
  • Liquid crystal display optional
  • Flow tube materials; PEEK® / 316L Stainless Steel or PEEK® / Glass
  • O-ring Viton or Nitrile, EPDM or Silicone
  • Process connections: 3/8″ John Guest, 1/2″ NPT or 1/2″ BSPP male
  • Bi-directional with indication of positive and negative flow
  • Immune for changes of fluid velocity profile and Reynolds number
  • No moving parts


pdf  Article Eureka Magazine March 2010
video  Atrato Video Presentation
zip  Atrato Interface Software 1.2.0.11 (s/n 012xxx)
zip  Atrato Interface Software 3.3.1.18 (s/n 014xxx and earlier)
zip  Atrato Interface Software 4.0.1.14 (s/n 015xxx and later)

zip  Atrato Interface Software 4.1.0 (s/n 015xxx and later)

zip  Atrato Interface Software 4.3.0 (s/n 015xxx and later)

zip  Atrato Interface Software 4.3.4 (s/n 015xxx and later)
pdf  Atrato Software Development Kit
zip  Atrato Software Development Kit – App3_2_25_UserSDK-015
pdf  Top 10 Tips For Selecting a Flowmeter
pdf  How to Specify Liquid Flowmeters
pdf  Selecting Liquid Flowmeters Below Half Inch Bore