Low Cost Field Mounted Ultrasonic Flowmeter
KATflow 100
![]() |
Specifications
- Transit-time correlation measurement
- Wall mounted unit with or without display
- One measurement channel
- Flow velocity range: 0.01 to 25 m/s (2 to 5000 ft/min)
- Resolution: 0.25 mm/s (0.05 ft/min)
- Repeatability: 0.15% of measured value ± 0.015 m/s (2.95 ft/min)
- Accuracy: Flow velocity: ± 0.5% of measured value Volume flow: ± 1 to 3% of measured value depending on application
- Turn down ratio: 1 / 100
- Serial interface RS 232; RS 485 OR Modbus RTU optional
- Outputs: current (HART), voltage and digital (pulse / relay)
- Non-invasive: no pipeline disturbance or pressure loss
- Easy to install clamp-on sensors with no process interruption
- All commonly used pipe materials, pipe diameters 3/8″ to 118″
Multifunctional Field Mounted Ultrasonic Flow meter
KATflow 150
![]() |
Specifications
- Transit-time correlation measurement
- Dual DSP-technology for better measurement accuracy
- Wall mounted unit with graphic display
- One or two channels
- Flow velocity range: 0.01 to 25 m/s (2 to 5000 ft/min)
- Resolution: 0.25 mm/s (0.05 ft/min)
- Repeatability: 0.15% of measured value ± 0.015 m/s (2.95 ft/min)
- Accuracy: Flow velocity: ± 0.5% of measured value Volume flow: ± 1 to 3% of measured value depending on application
- Turn down ratio: 1 / 100
- Serial interface RS 232; RS 485 or Modbus RTU optional
- Data logger for up to 30,000 samples (optional > 100,000 samples)
- Outputs: current (HART), voltage and digital (pulse / relay)
- Input: current / 4 – wire Pt100 Temperature for energy measurement
- Non-invasive: no pipeline disturbance or pressure loss
- Easy to install clamp-on sensors with no process interruption
- All commonly used pipe materials, pipe diameters 3/8″ to 118″
ATEX Field Mounted Ultrasonic Flow meter
KATflow 170
![]() |
Specifications
- Explosion-proof field housing, pipe mounted, ATEX II 2G Ex de IIB T6
- Transit-time correlation measurement
- Dual DSP-technology for better measurement accuracy
- Wall mounted unit with graphic display
- One or two channels
- Flow velocity range: 0.01 to 25 m/s (2 to 5000 ft/min)
- Resolution: 0.25 mm/s (0.05 ft/min)
- Repeatability: 0.15% of measured value ± 0.015 m/s (2.95 ft/min)
- Accuracy: Flow velocity: ± 0.5% of measured value Volume flow: ± 1 to 3% of measured value depending on application
- Turn down ratio: 1 / 100
- Serial interface RS 232; RS 485 or Modbus RTU optional
- Data logger for up to 30,000 samples (optional > 100,000 samples)
- Outputs: current (HART), voltage and digital (pulse / relay)
- Input: current / 4 – wire Pt100 Temperature Compensation
- Non-invasive: no pipeline disturbance or pressure loss
- Easy to install clamp-on sensors with no process interruption
- All commonly used pipe materials, pipe diameters 3/8″ to 118″