Transmitters / Switch for Moisture Content in Oil

 

Transmitters for Moisture Content in Oil
Series EE36
transmitter for moisture

 

  • Water activity range: 0 - 1aw
  • Water content ranges: 0 - 100 / 0 - 500 / 0 - 1000 / 0 - 10000 ppm
  • Temperature range probe: -40 to 180 °C (-40 to 356 °F)
  • Outputs choice of:
        Temperature (T)
        Water activity (aw)
        Water content in mineral transformer oil (ppm)
        Water content in lubrication or non-mineral transformer oil (ppm)
  • Analogue outputs: 0 - 5V / 0 - 10V / 4 - 20 mA / 0 - 20 mA
  • Probe pressure tight: 0.01 to 20 bar (0.15 to 290 psi)
  • Two freely scaleable analogue outputs
  • Probe cable length up to 10 meter (33 feet)
  • RS 232 interface plus configuration software
  • Optional alarm output and graphical LC display
  • Optional ball valve set
  • Calibrated against NIST traceable factory standar

 

Transmitter / Switch for Moisture Content in Oil
Series EE381 / EE385
EE381 small

 

  • Water activity range: 0 - 1aw
  • Water content ranges: 0 - 100 / 0 - 500 / 0 - 1000 ppm
  • Accuracy: ± 0.02aw (0 - 0.9aw) / ± 0.03aw (0.9 - 1aw)
  • Outputs choice of:
        Temperature (T)

        Water activity (aw)

        Water content in mineral transformer oil (ppm)

        Water content in lubrication or non-mineral transformer oil (ppm)
  • Temperature range probes: -40 to 80 °C (-40 to 176 °F)
  • Pressure ranges: 20 bar (290 psi) / 100 bar (1450 psi)
  • Two freely scaleable analogue outputs - Transmitter EE38-T
  • Two potential-free relays; 30 Vdc, 0.6 A / 35 Vac, 0.3 A - Switch EE38-S
  • RS 232 interface plus configuration software
  • Optional graphical LC display
  • Calibrated against NIST traceable factory standards

Intrinsically Safe Transmitters for Moisture Content in Oil
Series EE300Ex-HT
 
EE300Ex small ATEX-EX small

  

  • Water activity range: 0 - 1aw
  • Water content ranges: 0 - 100 / 0 - 500 / .......... / 0 - 100000 ppm
  • IS - ATEX II 1 G Ex ia IIC T6 Ga / II 1 D Ex ia IIIC T70°C Da IP65
  • Outputs choice of:     
       
    Temperature (T)
        Water activity (aw)
        Water content in mineral transformer oil (ppm)
        Water content in lubrication or non-mineral transformer oil (ppm)
  • Temperature range probe: -40 to 180 °C (-40 to 356 °F)
  • Pressure ranges: 20 bar (290 psi) / 300 bar (4300 psi)
  • Two freely scaleable outputs - 2-wire loop powered 4 - 20 mA
  • RS 232 interface plus configuration software
  • Optional graphical LC display
  • Calibrated against NIST traceable factory standards

 

Please note: Manual data files can be quite large, please be patient while downloading.
The manuals are for information purposes only and shouldn't be used for operating the instrument